BL(T) series stainless steel multi-stage centrifugal pump (afterwards called pump)boasts characters of high efficiency, low noise, steady operation, etc.The pump set adopts the non-self-priming vertical multi-stage structure, which makes a compact whole,its installation easy, its operation and maintenance convenient.
Provvista ta 'ilma |
BL |
BLT |
Filtration and transfer at waterworks |
â— |
â— |
Distribuzzjoni minn xogħlijiet tal-ilma |
â— |
â— |
Pressureboosting in mains |
â— |
â— |
Żieda fil-pressjoni f'binjiet, lukandi, eċċ. |
â— |
â— |
Pressure boosting for industrial water supply |
â— |
â— |
Industry |
|
|
Pressure boosting |
|
|
Process water systems |
â— |
â— |
Washing and cleaning systems |
â— |
â— |
Mini ta 'ħasil ta' vetturi |
â— |
â— |
Fire fighting systems |
â— |
â— |
Trasferiment ta 'likwidu |
|
|
Sistemi ta 'tkessiħ u arja kkondizzjonata (refriġeranti) |
â— |
â— |
Boiler feed and condensate systems |
â— |
â— |
Għodod tal-magni (lubrikanti li jkessħu) |
â— |
â— |
Aquafarming |
â— |
â— |
Trasferiment |
|
|
Żejt u alkoħol |
â— |
â— |
Glikol u likwidi li jkessħu |
â— |
â— |
Trattament ta 'l-ilma |
|
|
Ultra-filtration systems |
â— |
â ‹‹ |
Reverse osmosis systems |
â— |
â ‹‹ |
Softening, ionising, demineralizing systems |
â— |
â ‹‹ |
Sistemi ta 'distillazzjoni |
â— |
â ‹‹ |
Separaturi |
â— |
â ‹‹ |
Banjijiet tal-għawm |
â— |
â— |
irrigazzjoni |
|
|
Field irrigation(flooding) |
â— |
â— |
Irrigazzjoni ta 'bexxiexi |
â— |
â— |
Irrigazzjoni ta 'għalf f'taqtir |
â— |
â— |
Energy Efficiency Standard (IEC60034)
Calculation Of minimum Inlet Pressure
If the pressure in pump is lower than the vapour pressure of medium, cavitation will occur, which will affect the performance of pump. To avoid the cavitation and ensure the pump inlet has a minimum pressure, maximum suction head should be calculated as following:
H=Pbx10.2-NPSH-Hf-hv-Hs
Pb: Pressjoni atmosferika, bar (F'sistema ta 'pajpijiet viċin, tista' titqies bħala l-pressjoni tas-sistema);
NPSH: Net positive suction head, m (Value at maximum flow of Q-NPSH curve);
Hf: Suction pipe line loss (Value at maximum flow of corresponding pipeline);
Hv: Pressjoni medja tal-fwar, m (Pressjoni medja tal-fwar f'temperatura korrispondenti, il-mezz default huwa l-ilma, kif muri fil-figura 4 fuq il-lemin);
Hs: Il-marġini tas-sigurtà, m, il-valur ġenerali huwa 0.5.
Calculation result: if H is positive, the pump is installed in suction way, otherwise, it is installed in downdraft way.
Nota: Mhuwiex meħtieġ li jsir kalkolu ta 'hawn fuq taħt kondizzjonijiet ġenerali. Meta nużaw il-pompa biss fis-sitwazzjonijiet li ġejjin għandna bżonn li nikkalkulaw l-H:
1. Medium temperature is high;
2.The velocity of flow is larger than rated value;
3.Suction head is big or inlet pipeline is long;
Pressjoni 4.System huwa żgħir;
Kondizzjoni 5.Inlet huwa ħażin.
Selection Of Pumps
L-għażla tal-pompi għandha tkun ibbażata fuq:
Il-punt tat-tħaddim tal-pompa.
Dejta dimensjonali bħal telf ta 'pressjoni bħala riżultat tad-differenzi fl-għoli, telf ta' frizzjoni fis-sistema tal-pajpijiet,
Effiċjenza tal-pompa eċċ.
Materjali tal-pompa
Pump connections
Commonly used mechanical seal configuration tables
1. Duty point of the pump:
Minn punt ta 'xogħol huwa possibbli li tagħżel pompa fuq il-bażi tal-kurvi tal-kurva murija f' "kurvi tal-prestazzjoni / tekniċi" data.2. Dimensional data:
Meta tingħata daqs pompa dan li ġej għandu jittieħed kontabilità: “Fluss meħtieġ u pressjoni fil-punt tat-tluq.” Telf ta 'pressjoni bħala riżultat ta' differenzi fl-għoli. għal Fig.1) Jista '"L-aħjar effiċjenza fil-punt tad-dazju stmat." Valur NPSH. "Għall-kalkolu tal-valur NPSH, ara l-kurva korrispondenti tal-kurva.3. Effiċjenza tal-pompa:
Before determining the best efficiency point, the operation pattern of the pump needs to be identified. If the pump expected to operate as the same duty point, then select a BL pump which is operating at a duty point corresponding with the best efficiency of the pump.Billi l-pompa hija mkejla fuq il-bażi ta 'l-ogħla fluss possibbli, huwa importanti li dejjem ikollha l-punt tad-dazju fuq il-lemin fuq il-kurva ta' effiċjenza (eta) sabiex l-effiċjenza tinżamm għolja meta l-fluss jinżel.
4. Materjal tal-pompa:
L-għażla tal-konnessjoni tal-pompa tiddependi fuq il-pressjoni nominali u x-xogħol tal-pajpijiet. il-pompa toffri firxa wiesgħa ta 'konnessjoni ftexible bħal:
5. Tabelli ta 'konfigurazzjoni ta' siġilli mekkaniċi użati komunement
Field Applikazzjoni | Tip ta 'siġill tax-xaft | Materjal li jissiġilla x-xaft | ||||||||||
Normali | Speċjali | 1 | 2 | 3 |
4
5
|
Ċavetta tat-tip | ||||||
Parti li ddur | Kodiċi | Stationary part | Kodiċi | Elastomers | Kodiċi | Compression spring | Kollor | Kodiċi | ||||
0a sa + 90a 'ilma nadif | â— | Grafita | A | SiC | S | FPM | F | SUS304 | Ċ | ASFC | ||
0a sa + 90a 'ilma nadif | â— | WC | W | Grafita | A | FPM | F | SUS304 | Ċ | WAFC | ||
+90℃ to +120℃ corrosion resistance | â— | SiC | S | SiC | S | EPDM | E | SUS304 | Ċ | SSEC | ||
up to 0℃ | â— | WC | W | WC | W | EPDM | E | SUS304 | Ċ | WWEC |
Mechanical seal type | Pump model | d1 | d2 | h |
NJK | BL(T)2/4 | 12 | 12 | 55 |
BL (T) 8/12/16/20 | 16 | 16 | 57.5 | |
BL (T) 32/45/60/90 | 22 | 22 | 72 | |
NDA | BW(J)2/4 | 12.7 | 16 | 32 |
BW (J) 8/16 | 17.4 | 20 | 33.5 |
Mudell |
Numru tal-kurva |
BL (T) 2,4 |
2 |
BL (T) 8,12,16,20 |
3 |
BL (T) 32-2-2 ~ BL (T) 32-7 |
1 |
BL (T) 32-8-2 ~ BL (T) 32-12 |
4 |
BL (T) 32-13 ~ BL (T) 32-15-2 |
5 |
BL (T) 45-2-2 ~ BL (T) 45-6 |
1 |
BL(T)45-7-2~BL(T)45-9 |
4 |
BL(T)45-10-2~BL(T)45-13-2 |
5 |
BL(T)64-2-2~BL(T)64-5-2 |
1 |
BL(T)64-5-1~BL(T)64-8 |
4 |
BL(T)90-2-2~BL(T)90-4-2 |
1 |
BL(T)90-4~BL(T)90-6 |
4 |
BL (T) 120-150 |
6 |
Il-limiti tal-pressjoni u t-temperatura huma murija fil-fig.4 li ġej, il-pressjoni u t-temperatura għandhom ikunu fil-muri fil-fig. 4.
Meta l-pompa tkun qed taħdem fil-post fejn it-temperatura ta 'l-ambjent tkun ogħla minn 40a jew l-altitudni tkun ogħla minn 1000m, il-qawwa tal-ħruġ tal-mutur P2 tonqos minħabba t-tkessiħ ħażin ikkawżat minn densità baxxa ta' l-arja. għandhom ikunu mgħammra b’mutur ta ’qawwa għolja.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Flanġ standard PN25-40 / DN100, fuq talba.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Flanġ standard PN25-40 / DN100, fuq talba.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.
Huwa rrakkomandat li jintuża fil-firxa tal-lift.